Summary for Test 2022-10-29-7-3
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 993771 DEA: 07325204 EFIS: 0716000082 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-210-R36.7/R37.1 |
| Award Date | 02/15/2022 |
| Closeout Date | 01/29/2024 |
| Work Description | San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs |
| Location Description | Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING |
| QA Service Level | 1 (Verified on 04/21/2022) |
Sample Information
| Sample Taken Date | 10/29/2022 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2022 |
| Sample type | Quality Assurance | A brief description of the sample | 4X8 PCC cylinders |
| The quantity of what the sample constitutes | 130 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Samar | Last name of sampler or witnessed by | Saad |
| Title of sampler | Assistant Structure Representative | Telephone number of sampler | |
| Laboratory sample identification | 22-0339 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | National Ready Mix | Transportation Laboratory (TL) Number | 07-325204-005 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S72500 |
|---|---|---|---|
| The truck number from where the sample was collected | 20121 | The batch plant ticket number from where the sample was collected | 647025 |
| Concrete batch plant | National Ready Mix | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-10-29-7
DIME Test ID: 2022-10-29-7-3
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-11-28
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 11/19/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.03 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 55971 lb
Maximum load on cylinder 2: 56135 lb
Maximum load on cylinder 3: 55955 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 21 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.76 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 4386.4 psi
Compressive strength of cylinder 2: 4444.6 psi
Compressive strength of cylinder 3: 4409.4 psi
Compressive strength (to nearest 10 psi): 4410 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/28/2022 ✔