Summary for Test 2016-10-12-8-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-171.8/173.8 |
Award Date | 11/04/2015 |
Closeout Date | 08/21/2018 |
Work Description | BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT. |
Location Description | In SBD County |
QA Service Level | 1 (Verified on 10/19/2015) |
Sample Information
Sample Taken Date | 10/12/2016 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/17/2016 |
Sample type | Quality Assurance | A brief description of the sample | Lenton Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Faisal | Last name of sampler or witnessed by | Zahlout |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Gerdau, Erico | Transportation Laboratory (TL) Number | C001 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | Erico | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #8 | Coupler Model | EL25A2 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | L8278 | Rebar Heat Number(s) | 6502492202 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2016-10-12-8
DIME Test ID: 2016-10-12-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-10-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/19/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #8/25mm | 0.79 | 0 | 74050 | 93734 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/19/2016 ✔