Summary for Test 2022-11-17-23-3

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/17/2022 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/17/2022
Sample typeQuality Control A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes2 qts From where was the sample collectedSource
First name of sampler or witnessed byTom Last name of sampler or witnessed byReneau
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWestern Emulsions - White City OR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierWestern Emulsion - White City Emulsion Plant - White City OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2022-11-17-23
DIME Test ID: 2022-11-17-23-3
Testing Lab: Western Emulsions, Incorporated - White City Emulsion
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2022-11-21

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Elena Hubert
Date of test: 11/17/2022
Observed Flash Point: 298 C
Ambient Barometric Pressure: 772.4 mmHg
Cleveland Open-Cup Flash Point in Celsius: 298 C
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/21/2022