Summary for Test 2022-11-07-7-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
| Award Date | 04/21/2020 |
| Closeout Date | 12/02/2025 |
| Work Description | Panther Creek & Hunter Creek Bridges |
| Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
| QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
| Sample Taken Date | 11/07/2022 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/17/2022 | Sample type | Quality Assurance |
| A brief description of the sample | #9 Barlock couplers | The quantity of what the sample constitutes | 40 each |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Greg |
| Last name of sampler or witnessed by | Thompson | Title of sampler | Associate Steel Inspector |
| Telephone number of sampler | 5103767155 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | PJ's Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-170-22 | |
| Structure unique identifier | Structure name | Panther Creek | |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A615 |
| Material Grade | 60 | Rebar Manufacturer | Nucor |
| Coupler Manufacturer | Dayton Barlock | Intermediate Assembler or Fabricator | NorthCoast Steel |
| Rebar Size | #9 | Coupler Model | D250L Bar Lock |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | MM20102405 | Rebar Heat Number(s) | 3500027977 |
| Rebar Size 2 | Coupler Unique ID | SL-17-06 |
Test Details
DIME Sample ID: 2022-11-07-7
DIME Test ID: 2022-11-07-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2022-11-21
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/21/2022
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | No. 9/29mm | 1 | 0 | 1 | 97029 | 97029 | Service Splice | spaine |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 11/21/2022 ✔