Summary for Test 2022-08-24-93-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 215753
DEA: 050N72U4
EFIS: 0520000169
DIST-CO-RTE-PM05-SB-101-4.4/R7.7
Award Date03/01/2021
Closeout DateNot set
Work DescriptionPlease cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description101 freeway in Summerland, CA
QA Service Level1 (Verified on 05/06/2021)

Sample Information

Sample Taken Date08/24/2022 Sample Unique Key93
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2022
Sample typeQuality Control A brief description of the samplestructural concrete
The quantity of what the sample constitutes1 per batch From where was the sample collectedJob Site
First name of sampler or witnessed byAdrian Last name of sampler or witnessed byPlentywounds
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Mariatta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number725 A1ZOP
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected3431467
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-08-24-93
DIME Test ID: 2022-08-24-93-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-11-18

Test Results


Number of specimens: 2
Input Type: Calculated
Tester's full name: Eddie Mendez
Date of test: 09/21/2022
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): no data
Break Description of Cylinder 2 (if not 'cone'): no data
Average Compressive Strength (to nearest 10): 4820 lb/in^2
Compressive Strength of Cylinder 1: 4761 lb/in^2
Compressive Strength of Cylinder 2: 4820 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2022