Summary for Test 2022-11-03-58-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993703 DEA: 070W0404 EFIS: 0721000028 MINOR: 11A3471 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-90-0.9/T3.3 |
| Award Date | 06/09/2022 |
| Closeout Date | 02/05/2024 |
| Work Description | PCC GRINDING, SLAB REPLACEMENT, SLURRY SEAL & COLD PLANE AC PAVEMENT. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES AND CULVER CITY FROM ROUTE 1 TO SLAUSON AVENUE |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 11/03/2022 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/07/2022 |
| Sample type | Department Acceptance | A brief description of the sample | 3/4" WMA-A 220830A IRW LTR |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | 22-0342 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Irwindale | Transportation Laboratory (TL) Number | 1103B2 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220830A IRW LTR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-11-03-58
DIME Test ID: 2022-11-03-58-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-11-16
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 11/08/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7359.3 grams
Mass of oven-dry sample in air for Sample 1: 2549.2 grams
Mass of container filled with the sample and water for Sample 1: 8892.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.508
Theoretical maximum density at 25°C (77°F): 156.1 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/16/2022 ✔