Summary for Test 2022-09-16-58-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214986
DEA: 041J9704
EFIS: 0414000404
DIST-CO-RTE-PM04-SCL-17-2.8/13.94
Award Date04/30/2021
Closeout Date10/06/2025
Work DescriptionPAVING WITH RHMA, COLD PLANE AC, AND INSTALL CULVERT.
Location DescriptionSANTA CLARA COUNTY IN AND NEAR LOS GATOS, CAMPBELL AND SAN JOSE FROM HEBARD ROAD TO ROUTE 17/280 SEPARATION
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date09/16/2022 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/16/2022
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-O Batch Cold Feed
The quantity of what the sample constitutesPSUE 9 Bags of Cold Feed From where was the sample collectedManufacturer
First name of sampler or witnessed byFernando Last name of sampler or witnessed byVega
Title of samplerMREA Telephone number of sampler(510) 385-8171
Laboratory sample identificationSJ-091622-PSUE1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Aromas Batch Plant Transportation Laboratory (TL) NumberC964755
Inspector Lot Number from the Transportation Laboratory (TL) FormLot 1 Sublot 1 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeNot Applicable
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number959
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-09-16-58
DIME Test ID: 2022-09-16-58-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-11-15

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Fernando Vega
Date of test: 09/17/2022
Cumulative Percent Passing
%
100 %
100 %
100 %
99 %
81 %
33 %
10 %
6 %
5 %
4 %
3 %
2.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2022