Summary for Test 2016-10-05-7-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 210570 DEA: 100Y90U4 EFIS: 1015000055 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-99,15,163-18.4/23.0 |
| Award Date | 12/04/2015 |
| Closeout Date | 04/11/2017 |
| Work Description | PLACE JPCP (RSC), COLD PLANE AC PAVEMENT, AND INSTALL RAMP METERING. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON FROM 0.1 MILE SOUTH OF MARSH STREET PEDESTRIAN OVERCROSSING TO 0.1 MILE NORTH OF HAMMER LANE OVERCROSSING |
| QA Service Level | 1 (Verified on 09/23/2015) |
Sample Information
| Sample Taken Date | 10/05/2016 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/07/2016 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Mission City Rebar | Transportation Laboratory (TL) Number | C836026 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B914216 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | SE15100044 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 5 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Mission City Rebar |
| Welding Company | Mission City Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-10-05-7
DIME Test ID: 2016-10-05-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/10/2016
UTM: 75KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 1 | #5/16mm | 0.31 | 29646 | 95630 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 10/12/2016 ✔