Summary for Test 2016-09-29-9-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211723 DEA: 120N8804 EFIS: 1214000126 MINOR: 12A1641 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-1.12 |
| Award Date | Not set |
| Closeout Date | 06/21/2021 |
| Work Description | Replace safety lighting standards and refresh Signing and Striping for the SB 405 off ramp at Irvine Center Drive |
| Location Description | IRVINE, SOUTHBOUND RTE 405, AT EXIT RAMP TO IRVINE CENTER DRIVE |
| QA Service Level | 1 (Verified on 09/12/2016) |
Sample Information
| Sample Taken Date | 09/29/2016 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/03/2016 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
| The quantity of what the sample constitutes | 1 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | TNT Rebar Nucor | Transportation Laboratory (TL) Number | C970905 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L0213216 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | PL14104777 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 4 |
| Diameter of Hoop | 2'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-09-29-9
DIME Test ID: 2016-09-29-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-05
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/04/2016
UTM: 75KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | #4/13mm | 0.2 | 19001 | 95000 | Bar Broke in Heat Affected Area | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 10/5/2016 ✔