Summary for Test 2022-10-21-47-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date10/21/2022 Sample Unique Key47
Date that the sample was received by the laboratory/organization performing the testing10/21/2022 Sample typeQuality Assurance
A brief description of the sampleNative Material The quantity of what the sample constitutes200 Square Feet
From where was the sample collectedJob Site First name of sampler or witnessed byIan
Last name of sampler or witnessed bySnyder Title of sampler
Telephone number of sampler Laboratory sample identification22-2834
Linked DIME Sample ID The fabricator/manufacturer/facility namen/a
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedCTM 231 Test Holes
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-10-21-47
DIME Test ID: 2022-10-21-47-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-11-04

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Ian Snyder
Date of test: 10/21/2022
Gage No.: 37847
Test No.: 3
Nuclear By: Ian Snyder
Non-Bias Plan No.: 9
Depth: 12
Material No.: Subgrade
Material Type: Native
Impact By: Ian Snyder
Standard Count Density: 2113 g/cc
Count or Density 1: 301 g/cc
Count or Density 2: 326 g/cc
Count or Density 3: 318 g/cc
Standard Count Moisture: 712 g/cc
Moisture Count 1: 165 g/cc
Moisture Count 2: 156 g/cc
Moisture Count 3: 162 g/cc
Sum of Count or Density: 945 g/cc
Average of Count or Density: 315 g/cc
Sum of Moisture Count: 483 g/cc
Average of Moisture Count: 161 g/cc
Count Ratio Density: 0.15
Count Ratio Moisture: 0.23
Calculated Percent Relative Compaction: 95.6 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/4/2022 ✔