Summary for Test 2022-11-03-41-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 214336
DEA: 07302404
EFIS: 0713000488
DIST-CO-RTE-PM07-VEN-101-37/40
Award Date11/17/2020
Closeout Date09/24/2024
Work DescriptionPADRE JUAN REHAB
Location DescriptionVEN 101
QA Service Level1 (Verified on 02/26/2021)

Sample Information

Sample Taken Date11/03/2022 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/03/2022
Sample typeDepartment Acceptance A brief description of the sampleWCS PCC Aggregate
The quantity of what the sample constitutes700 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byHopkins
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Ventura - Portable PCC Transportation Laboratory (TL) NumberC110322C
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sampleJPCP Pavement The fabricator/manufacturer designation for the sample
The plant numberGranite Portable Jobsite Ventura A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberG3-21-PCC-250HPR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2022-11-03-41
DIME Test ID: 2022-11-03-41-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-11-07

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 11/04/2022
Cumulative Mass RetainedCumulative Percent Passing
522 grams
0 grams100 %
23 grams96 %
114 grams78 %
204 grams61 %
321 grams39 %
447 grams14 %
496 grams5 %
504 grams3 %
522 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/7/2022