Summary for Test 2022-06-13-87-5

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 66669
DEA: JMF-DATA
EFIS: JMF-DATA
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for storing JMF sample data
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/13/2022 Sample Unique Key87
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/13/2022
Sample typeQuality Control A brief description of the sampleCOLDFEED
The quantity of what the sample constitutes13 From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byEscobar
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameVernalis Aggregate Source Transportation Laboratory (TL) NumberNot set
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0002
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedTunnel Pile
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-13-87
DIME Test ID: 2022-06-13-87-5
Testing Lab: Granite Construction Company - Tracy
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2022-11-03

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Chris Escobar
Date of test: 11/02/2022
Weighted percentage of particles (by mass) that were flat and elongated: 0 %
Weighted percentage of particles (by mass) that were not flat and elongated: no data
General comments (publicly viewable) (Max 1000 characters): Submitted from JMF - Chris Escobar

Test was verified on 11/3/2022