Summary for Test 2022-09-12-61-4
Test performed: AASHTO T315-12Project Information
| Project Identifiers | Project ID: 993592 DEA: 120S8704 EFIS: 1221000056 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-55-0.2/T2.4 |
| Award Date | 04/21/2022 |
| Closeout Date | 12/28/2022 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RHMA-G. |
| Location Description | ORANGE COUNTY IN NEWPORT BEACH AND COSTA MESA FROM JUNCTION ROUTE 1 TO 0.4 MILE NORTH OF 19TH STREET |
| QA Service Level | 1 (Verified on 03/21/2022) |
Sample Information
| Sample Taken Date | 09/12/2022 | Sample Unique Key | 61 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/01/2022 | Sample type | Per Request |
| A brief description of the sample | PG Asphalt Binder | The quantity of what the sample constitutes | 1 Quart Can |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Jimmy |
| Last name of sampler or witnessed by | Pham | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0719-22 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan-Irwindale | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2022-09-12-61
DIME Test ID: 2022-09-12-61-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-11-28
Test Results
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 11/02/2022
Phase: Original binder
Phase Angle (δ) (for the 10 cycles): 87.6 degree
Dynamic Shear, G*/sin(δ): 1.40 kPa
(G*) x sin(δ)=: no data
General comments (publicly viewable) (Max 1000 characters): ORIGINAL DSR
Test was verified on 11/28/2022 ✔