Summary for Test 2022-10-21-39-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214666
DEA: 022H8104
EFIS: 0217000012
DIST-CO-RTE-PM02-TRI-299-1.67/45.12
Award Date03/03/2022
Closeout Date08/11/2023
Work DescriptionTRINITY CULVERTS
Location DescriptionCULVERT REHABILITATION IN TRINITY COUNTY NEAR SALYER AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF WHITE HOUSE GULCH ROAD TO 0.4 MILE WEST OF SLATTERY POND ROAD.
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date10/21/2022 Sample Unique Key39
Date that the sample was received by the laboratory/organization performing the testing10/21/2022 Sample typeDepartment Acceptance
A brief description of the sampleCombined Lime Treated 3/4-inch Type A Aggregate The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byJ.D.
Last name of sampler or witnessed byAtkinson Title of samplerConsultant
Telephone number of sampler Laboratory sample identificationD79177F
Linked DIME Sample ID The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA)
Transportation Laboratory (TL) Number858106 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::Shasta Ranch Aggregates
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedMathematically Combined Gradation per CT 384
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2022-10-21-39
DIME Test ID: 2022-10-21-39-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-10-31

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Darrell Valasek
Date of test: 10/31/2022
Cumulative Percent Passing
%
100 %
100 %
100 %
90 %
67 %
39 %
27 %
18 %
13 %
9 %
7 %
5.1 %
General comments (publicly viewable) (Max 1000 characters): Mathematically combined at 76.0% virgin aggregate and 24.0% reclaimed aggregate per CT 384

Test was verified on 10/31/2022 ✔