Summary for Test 2022-10-08-12-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 215220 DEA: 07210624 EFIS: 0719000068 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,SBD-71-1.8/R4.7&R0.0/R0.2 |
| Award Date | 02/05/2021 |
| Closeout Date | Not set |
| Work Description | PLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP. |
| Location Description | IN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE. |
| QA Service Level | 1 (Verified on 03/24/2021) |
Sample Information
| Sample Taken Date | 10/08/2022 | Sample Unique Key | 12 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/08/2022 |
| Sample type | Quality Assurance | A brief description of the sample | Native Material |
| The quantity of what the sample constitutes | 12,150 Square Feet | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Fernando | Last name of sampler or witnessed by | Carranza |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 22-2689 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | n/a | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-10-08-12
DIME Test ID: 2022-10-08-12-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-10-27
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Fernando Carranza
Date of test: 10/08/2022
Gage No.: 80489
Test No.: 1
Nuclear By: Fernando Carranza
Non-Bias Plan No.: 3
Depth: 8
Material No.: Subgrade
Material Type: Native
Impact By: Fernando Carranza
Standard Count Density: 2293 g/cc
Count or Density 1: 1228 g/cc
Count or Density 2: 1134 g/cc
Count or Density 3: 932 g/cc
Count or Density 4: 986 g/cc
Count or Density 5: 1297 g/cc
Standard Count Moisture: 807 g/cc
Moisture Count 1: 200 g/cc
Moisture Count 2: 172 g/cc
Moisture Count 3: 183 g/cc
Moisture Count 4: 200 g/cc
Moisture Count 5: 165 g/cc
Sum of Count or Density: 5577 g/cc
Average of Count or Density: 1115 g/cc
Sum of Moisture Count: 920 g/cc
Average of Moisture Count: 184 g/cc
Count Ratio Density: 0.49
Count Ratio Moisture: 0.23
Calculated Percent Relative Compaction: 96.9 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/27/2022 ✔