Summary for Test 2016-05-19-8-6

Test performed: CONCLP 3-16
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 210756
DEA: 043G4034
EFIS: 0412000101
DIST-CO-RTE-PM04-CC,SOL-80-13.4/14.1,0.0/0.6
Award Date01/05/2016
Closeout Date12/21/2017
Work DescriptionRESURFACE BRIDGE , INSTALL NEW JOINT SEAL..
Location DescriptionIN CONTRA COSTA AND SOLANO COUNTIESON THE CARQUINEZ BRIDGE (1958)
QA Service Level1 (Verified on 09/15/2015)

Sample Information

Sample Taken Date05/19/2016 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing05/19/2016 Sample typeQuality Control
A brief description of the samplepolyester resin The quantity of what the sample constitutes40000 lbs
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility namereichhold
Transportation Laboratory (TL) Numberc240494 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)0000975313
Batch Number0000975313 Mix number

Test Details

DIME Sample ID: 2016-05-19-8
DIME Test ID: 2016-05-19-8-6
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2016-09-22

Test Results


Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 09/22/2016
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 195 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.07
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 51.1 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2953 psi
Styrene ASTM D 2369 40% to 50 %: 44 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 470 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.6 grams
General comments (publicly viewable) (Max 1000 characters): approved by J.Sagar

Test was verified on 9/22/2016 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.