Summary for Test 2022-10-10-2-8
Test performed: ASTM B499-09r21Project Information
| Project Identifiers | Project ID: 993490 DEA: 051M4604 EFIS: 0519000154 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-1-44.5 |
| Award Date | 03/02/2022 |
| Closeout Date | 06/26/2023 |
| Work Description | CONSTRUCT RETAINING WALL, WIDENING SHOULDER AND PLACE HMA. Highway 1 at Coastlands Rd Soldier Pile Wall. |
| Location Description | MONTEREY COUNTY NEAR BIG SUR AT 1.0 MILE SOUTH OF PFEIFFER CANYON BRIDGE |
| QA Service Level | 1 (Verified on 01/19/2022) |
Sample Information
| Sample Taken Date | 10/10/2022 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/10/2022 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2" x 3-1/2" A449 Carriage Bolts | The quantity of what the sample constitutes | 22 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Lund | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 1-385-447-0624 | Laboratory sample identification | na |
| Linked DIME Sample ID | na | The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc. |
| Transportation Laboratory (TL) Number | na | Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-220-22 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 20815170 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | A449 |
| Bolt Length(s) | 3-1/2" | Nut Specification | na |
| Washer Specification | na | Finish | HDG |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 58498 |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2022-10-10-2
DIME Test ID: 2022-10-10-2-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2022-10-24
Test Results
Input Type: Calculated
Tester's full name: Ruben Macias
Date of test: 10/20/2022
Sample No.: 1D
Rocap Number: no data
Heat Number(s): 20815170
Mfg. Lot Number: B390-220-22
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A449 G
Size: .5 in
Bolt Length: 3.5 in
Measurement Average: 4.4 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/24/2022 ✔