Summary for Test 2022-10-14-24-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215057
DEA: 010F5304
EFIS: 0116000018
DIST-CO-RTE-PM01-HUM-299,200-R1.8,R2.7
Award Date09/02/2020
Closeout Date09/21/2023
Work DescriptionRAISE BRIDGE AND HMA PAVING
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA AT ROUTE 200/299 SEPARATION
QA Service Level1 (Verified on 07/24/2020)

Sample Information

Sample Taken Date10/14/2022 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing10/17/2022 Sample typeQuality Assurance
A brief description of the sampleZap Screwlok Type 2 Couplers The quantity of what the sample constitutes150 Couplers
From where was the sample collectedJob Site First name of sampler or witnessed byJarred
Last name of sampler or witnessed byBurrows Title of samplerSR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVinton Steel
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelZap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM20104043 Rebar Heat Number(s)2211937
Rebar Size 2 Coupler Unique IDSL-17-03

Test Details

DIME Sample ID: 2022-10-14-24
DIME Test ID: 2022-10-14-24-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2022-10-20

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/18/2022
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 8/25mm200.797670097088service splicespaine

General comments (publicly viewable) (Max 1000 characters): service splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 10/20/2022 ✔