Summary for Test 2022-10-14-24-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 215057 DEA: 010F5304 EFIS: 0116000018 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299,200-R1.8,R2.7 |
| Award Date | 09/02/2020 |
| Closeout Date | 09/21/2023 |
| Work Description | RAISE BRIDGE AND HMA PAVING |
| Location Description | HUMBOLDT COUNTY NEAR ARCATA AT ROUTE 200/299 SEPARATION |
| QA Service Level | 1 (Verified on 07/24/2020) |
Sample Information
| Sample Taken Date | 10/14/2022 | Sample Unique Key | 24 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/17/2022 | Sample type | Quality Assurance |
| A brief description of the sample | Zap Screwlok Type 2 Couplers | The quantity of what the sample constitutes | 150 Couplers |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jarred |
| Last name of sampler or witnessed by | Burrows | Title of sampler | SR |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Camblin Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Vinton Steel |
| Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | |
| Rebar Size | #8 | Coupler Model | Zap Screwlok |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | MM20104043 | Rebar Heat Number(s) | 2211937 |
| Rebar Size 2 | Coupler Unique ID | SL-17-03 |
Test Details
DIME Sample ID: 2022-10-14-24
DIME Test ID: 2022-10-14-24-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2022-10-20
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/18/2022
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | No. 8/25mm | 2 | 0 | 0.79 | 75311 | 95330 | service splice | spaine |
General comments (publicly viewable) (Max 1000 characters): service splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.