Summary for Test 2022-09-22-63-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date09/22/2022 Sample Unique Key63
Date that the sample was received by the laboratory/organization performing the testing09/22/2022 Sample typeDepartment Acceptance
A brief description of the sampleStructural Backfill Material The quantity of what the sample constitutes1833 sy
From where was the sample collectedJob Site First name of sampler or witnessed byArnold
Last name of sampler or witnessed byTruong Title of samplerMREA
Telephone number of sampler213-808-4582 Laboratory sample identification22-2493
Linked DIME Sample ID The fabricator/manufacturer/facility nameStructural Backfill
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleStructural Backfill
The fabricator/manufacturer designation for the sampleStructural Backfill A detailed description of where the material sample was collectedStructure Backfill
Where the material sample would have been placed if not sampledroadway

Test Details

DIME Sample ID: 2022-09-22-63
DIME Test ID: 2022-09-22-63-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-10-17

Test Results


Method Type:: Direct Read
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 09/22/2022
Gage No.: 60203
Test No.: 2493
Nuclear By: Arnold Truong
Non-Bias Plan No.: 1
Depth: 11
Material No.: structural backfill
Material Type: Structural Backfill
Impact By: Arnold Truong
Standard Count Density: 2.341 g/cc
Count or Density 1: 2.24 g/cc
Count or Density 2: 2.22 g/cc
Count or Density 3: 2.21 g/cc
Count or Density 4: 2.24 g/cc
Count or Density 5: 1.98 g/cc
Standard Count Moisture: 0.649 g/cc
Moisture Count 1: 0.16 g/cc
Moisture Count 2: 0.16 g/cc
Moisture Count 3: 0.16 g/cc
Moisture Count 4: 0.15 g/cc
Moisture Count 5: 0.12 g/cc
Sum of Count or Density: 10.89 g/cc
Average of Count or Density: 2.18 g/cc
Sum of Moisture Count: 0.75 g/cc
Average of Moisture Count: 0.15 g/cc
Calculated Percent Relative Compaction: 92.8 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/17/2022 ✔