Summary for Test 2022-09-15-14-16
Test performed: ASTM B499-09r21Project Information
Project Identifiers | Project ID: 214337 DEA: 080E33U4 EFIS: 0817000075 |
---|---|
DIST-CO-RTE-PM | 08-SBD-115-R7.3/R10.0 |
Award Date | 04/26/2021 |
Closeout Date | Not set |
Work Description | ADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG |
Location Description | SAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 09/15/2022 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2022 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" bolt assembly components |
The quantity of what the sample constitutes | 2 Lots of 1/2" bolt Assy Components | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Leach |
Title of sampler | QAI | Telephone number of sampler | 7072903887 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | St. Louis Screw & Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S38-068-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0157729, TT0157731 |
---|---|---|---|
Heat Number(s) | 10771000, CR10525360-32 | Nut Mfg. Lot Number(s) | E931C2 |
Washer Mfg. Lot Number(s) | 19228 Flat, 3650 Lock, G10451 Bevel | Bolt Specification | ASTM F3125, Grade A325 |
Bolt Length(s) | 1-1/4", 2-3/4" | Nut Specification | ASTM A563, Grade DH |
Washer Specification | ASTM F436-1 | Finish | ASTM A153, ASTM A153 |
Diameter/Size | 1/2" (both) | Bolt Mfg. Lot Number | E499H1, 807489 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2022-09-15-14
DIME Test ID: 2022-09-15-14-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2022-10-17
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 10/11/2022
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: E931C2
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH
Size: .5 in
Bolt Length: no data
Measurement Average: 2.98 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/17/2022 ✔