Summary for Test 2016-08-11-3-3
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 210888 DEA: 072750U4 EFIS: 0715000283 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-33,101-0.9/T5.82.3/13.8 |
| Award Date | 03/14/2016 |
| Closeout Date | 07/23/2019 |
| Work Description | CONSTRUCT STORM WATER TREATMENT BMP. |
| Location Description | CONSTRUCT STORM WATER TREATMENT BMP. |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 08/11/2016 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/16/2016 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 6 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | PANTALEON |
| Last name of sampler or witnessed by | RIVERA | Title of sampler | NP |
| Telephone number of sampler | 805-906-1656 | Laboratory sample identification | 939-SRL23 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | GRIMES CANYON |
| Transportation Laboratory (TL) Number | 23 | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Unknown | Structure name | Unknown |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S72500 |
|---|---|---|---|
| The truck number from where the sample was collected | NP | The batch plant ticket number from where the sample was collected | NP |
| Concrete batch plant | NP | The fabricator/manufacturer designation for the sample | NP |
| A detailed description of where the material sample was collected | NP | Where the material sample would have been placed if not sampled | TORN RIVERA POC |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-08-11-3
DIME Test ID: 2016-08-11-3-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-09-08
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 09/08/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 134480 lb
Maximum load on cylinder 2: 137200 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4740.2 psi
Compressive strength of cylinder 2: 4836.1 psi
Compressive strength (to nearest 10 psi): 4790 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/8/2016 ✔