Summary for Test 2016-09-06-6-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211319
DEA: 100Y5714
EFIS: 1014000162
DIST-CO-RTE-PM10-STA-99-R17.3/M18.9
Award Date06/09/2016
Closeout Date04/09/2018
Work DescriptionINSTALL AUTOMATED WARNING SYSTEM AND CONSTRUCT MVP.
Location DescriptionSTANISLAUS COUNTY IN MODESTO FROM 0.5 MILE NORTH OF KANSAS AVENUE OVERCROSSING TO 0.4 MILE NORTH OF CARPENTER ROAD/BRIGGSMORE OVERCROSSING
QA Service Level1 (Verified on 06/23/2016)

Sample Information

Sample Taken Date09/06/2016 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing09/07/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byGreg
Last name of sampler or witnessed byThompson Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) NumberC836016 Inspector Lot Number from the Transportation Laboratory (TL) FormB911516
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)582535
Hoop Manufacturer Lot Number(s)H01 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerEVRAZ
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-09-06-6
DIME Test ID: 2016-09-06-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-09-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/08/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12H01#4/13mm0.21855692780necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 9/8/2016 ✔