Summary for Test 2022-08-11-77-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 993609
DEA: 09388804
EFIS: 0921000038
DIST-CO-RTE-PM09-KER-58-R123.0/R125.3
Award Date04/21/2022
Closeout Date10/13/2022
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location DescriptionIN KERN COUNTY ABOUT 10 MILES EAST OF MOJAVE FROM 4.6 MILES TO 2.3 MILES WEST OF CALIFORNIA CITY BOULEVARD
QA Service Level1 (Verified on 03/28/2022)

Sample Information

Sample Taken Date08/11/2022 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/13/2022
Sample typeVerification A brief description of the samplePSUE3/4" HMA-A-SP R15 1.0% LSM
The quantity of what the sample constitutes8 Bags Agg., 2 Bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byS Last name of sampler or witnessed byAhumada
Title of sampler Telephone number of sampler
Laboratory sample identification0631A-22 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston-Lebec Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-15-0068
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant numberGRF 22 G3 1 A detailed description of where the material sample was collectedBelt Cut at Griffith, Edmonston-LEBEC
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-08-11-77
DIME Test ID: 2022-08-11-77-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2022-11-01

Test Results


Input Type: Measured
Tester's full name: Amir Behjati
Date of test: 09/21/2022
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 972 grams
Mass of the pycnometer with water (B): 653.4 grams
Mass of the oven dried sample (before pycnometer) (A): 491 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.707
Bulk specific gravity (SSD Basis): 2.756
Apparent specific gravity: 2.848
Absorption: 1.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/1/2022