Summary for Test 2016-07-20-13-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/20/2016 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/02/2016 |
Sample type | Quality Assurance | A brief description of the sample | A536 Ductile Iron |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Karen | Last name of sampler or witnessed by | Baker |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Stressteel Farrar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | G206 |
---|---|---|---|
Part Number (s) | ACS 12 6 AH | Material Specification | A536 |
Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar |
Prestressing Manufacturer | Stressteel |
Test Details
DIME Sample ID: 2016-07-20-13
DIME Test ID: 2016-07-20-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-09-07
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Arnold
Date of test: 09/06/2016
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | G206 | 0.4985 | 0.1952 | 65201 | 112250 | 9.5 | Arnold | |
2 | G206 | 0.4983 | 0.195 | 64878 | 112640 | 10 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 9/7/2016 ✔