Summary for Test 2022-07-08-113-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993535
DEA: 081M1104
EFIS: 0821000078
DIST-CO-RTE-PM08-SBD-215-10.0/17.2
Award Date03/14/2022
Closeout Date12/05/2022
Work DescriptionHMA, COLD PLANE AC PAVEMENT, AND TRAFFIC STRIPE TAPE.
Location DescriptionSAN BERNARDINO COUNTY?FROM 0.1 MILE NORTH OF 27TH STREET TO 0.1 MILE SOUTH OF DEVORE ROAD
QA Service Level1 (Verified on 02/21/2022)

Sample Information

Sample Taken Date07/08/2022 Sample Unique Key113
Date that the sample was received by the laboratory/organization performing the testing07/09/2022 Sample typeDepartment Acceptance
A brief description of the sample3/4" HMA-A-SP-R23 0.5% LAS The quantity of what the sample constitutes1 Bag of Combined Aggregate
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-San Bernardino Portable
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0137, 91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number223506 A detailed description of where the material sample was collectedBelt Cut at Vulcan AC Drum Plant San Bernardino
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-08-113
DIME Test ID: 2022-07-08-113-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-09-27

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Kalpesh Patel
Date of test: 07/12/2022
Cumulative Percent Passing
100 %
100 %
100 %
99 %
81 %
70 %
52 %
34 %
22 %
15 %
10 %
7 %
4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/27/2022