Summary for Test 2022-09-07-77-7

Test performed: CTM 301-March 2000

Project Information

Project IdentifiersProject ID: 993505
DEA: 022J4404
EFIS: 0221000078
DIST-CO-RTE-PM02-LAS-139-38.0/43.0
Award Date03/07/2022
Closeout Date05/24/2023
Work DescriptionREPLACE AC SURFACING, ASPHALT RUBBER BINDER, SEAL COAT & HMA OVERLAY.
Location DescriptionLASSEN COUNTY ABOUT 37 MILES NORTH OF SUSANVILLE FROM 4.3 MILES NORTH OF SOUTH GRASSHOPPER ROAD TO 0. 2 MILE SOUTH OF TERMO GRASSHOPPER ROAD
QA Service Level1 (Verified on 01/18/2022)

Sample Information

Sample Taken Date09/07/2022 Sample Unique Key77
Date that the sample was received by the laboratory/organization performing the testing09/07/2022 Sample typeDepartment Acceptance
A brief description of the sample4 bags of Shoulder Backing The quantity of what the sample constitutes3000 tons
From where was the sample collectedManufacturer First name of sampler or witnessed byJoe
Last name of sampler or witnessed byDelgado Title of samplerConsultant
Telephone number of sampler Laboratory sample identificationD79154
Linked DIME Sample ID The fabricator/manufacturer/facility nameHat Creek Construction and Materials – Shaw Pit (Lookout, CA)
Transportation Laboratory (TL) Number841604 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-25-0008::Shaw Pit
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-09-07-77
DIME Test ID: 2022-09-07-77-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2022-09-27

Test Results


How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Mills, Rios Dorado, and Hickey
Date of test: 09/15/2022
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 87 %
As Received Gradation, Percent Passing 3/4 in. sieve: 74 %
As Received Gradation, Percent Passing 1/2 in. sieve: 60 %
As Received Gradation, Percent Passing 3/8 in. sieve: 52 %
As Received Gradation, Percent Passing #4 sieve: 37 %
As Received Gradation, Percent Passing #8 sieve: 28 %
As Received Gradation, Percent Passing #16 sieve: 23 %
As Received Gradation, Percent Passing #30 sieve: 18 %
As Received Gradation, Percent Passing #50 sieve: 15 %
As Received Gradation, Percent Passing #100 sieve: 12 %
As Received Gradation, Percent Passing #200 sieve: 10 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 84 %
As Used Gradation, Percent Passing 1/2 in. sieve: 68 %
As Used Gradation, Percent Passing 3/8 in. sieve: 59 %
As Used Gradation, Percent Passing #4 sieve: 47 %
As Used Gradation, Percent Passing #8 sieve: 31 %
As Used Gradation, Percent Passing #16 sieve: 25 %
As Used Gradation, Percent Passing #30 sieve: 20 %
As Used Gradation, Percent Passing #50 sieve: 17 %
As Used Gradation, Percent Passing #100 sieve: 14 %
As Used Gradation, Percent Passing #200 sieve: 11 %
Horizontal pressure (specimen 1): 0.08 MPa
Displacement (specimen 1): 5.03
Horizontal pressure (specimen 2): 0.19 MPa
Displacement (specimen 2): 4.43
Horizontal pressure (specimen 3): 0.57 MPa
Displacement (specimen 3): 3.64
R value (specimen 1): 86.4
R value (specimen 2): 73
R value (specimen 3): 39
R value: 68
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/27/2022 ✔