Summary for Test 2022-08-12-49-2
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 993609 DEA: 09388804 EFIS: 0921000038 |
---|---|
DIST-CO-RTE-PM | 09-KER-58-R123.0/R125.3 |
Award Date | 04/21/2022 |
Closeout Date | 10/13/2022 |
Work Description | COLD PLANE AC PAVEMENT AND PLACE RHMA-G. |
Location Description | IN KERN COUNTY ABOUT 10 MILES EAST OF MOJAVE FROM 4.6 MILES TO 2.3 MILES WEST OF CALIFORNIA CITY BOULEVARD |
QA Service Level | 1 (Verified on 03/28/2022) |
Sample Information
Sample Taken Date | 08/12/2022 | Sample Unique Key | 49 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2022 |
Sample type | Department Acceptance | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | s | Last name of sampler or witnessed by | Ahumada |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0632-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Griffith Edmonston-Lebec | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-12-49
DIME Test ID: 2022-08-12-49-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2022-11-21
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 09/21/2022
Time of test: 8:35 HH:MM
Test Temperature: 135 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 81 %
Viscosity reading #1 (A) : 0.408 Pa-s
Viscosity reading #2 (B) : 0.405 Pa-s
Viscosity reading #3 (C): 0.409 Pa-s
Average viscosity: 0.407 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/21/2022 ✔