Summary for Test 2016-08-26-5-1
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 208967 DEA: 110223U4 EFIS: 1112000102 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5,89-R29.1/R30.5 |
| Award Date | 12/18/2014 |
| Closeout Date | 02/04/2022 |
| Work Description | REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT |
| QA Service Level | 1 (Verified on 01/21/2015) |
Sample Information
| Sample Taken Date | 08/26/2016 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/30/2016 | Sample type | Quality Assurance |
| A brief description of the sample | A536 Ductile Iron | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Debbie |
| Last name of sampler or witnessed by | Ozuna | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Manchester Metals |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 24H15 |
|---|---|---|---|
| Part Number (s) | 68 12 246 216 | Material Specification | A536 |
| Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Manchester Metals |
| Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2016-08-26-5
DIME Test ID: 2016-08-26-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-09-02
Test Results
Number of Samples: 1
Input Type: Calculated
Tester's full name: Arnold
Date of test: 09/01/2016
UTM: 67KIP
Temperature: 72 F
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 24H15 | 0.5 | 0.1963 | 49710 | 79170 | 16.1 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 9/2/2016 ✔