Summary for Test 2022-09-07-73-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993555 DEA: 061C4304 EFIS: 0621000166 |
---|---|
DIST-CO-RTE-PM | 06-MAD-41,99-9.2/11.7,0.0/1.5 |
Award Date | 04/07/2022 |
Closeout Date | 11/16/2023 |
Work Description | COLD PLANE AC, PLACE RHMA-G AND HMA (TYPE A). |
Location Description | MADERA COUNTY NEAR MADERA ON ROUTE 41 FROM 0.7 MILE SOUTH OF ROAD 209 TO 0.3 MILE NORTH OF ROAD 208 AND ON ROUTE 99 FROM MADERA COUNTY LINE TO 0.7 MILE SOUTH OF AVENUE 8 OVERCROSSING |
QA Service Level | 1 (Verified on 02/11/2022) |
Sample Information
Sample Taken Date | 09/07/2022 | Sample Unique Key | 73 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/15/2022 |
Sample type | Department Acceptance | A brief description of the sample | 1/2 RHMA-G |
The quantity of what the sample constitutes | 3 Boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | G | Last name of sampler or witnessed by | Litt |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 022-047 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Madera Plant | Transportation Laboratory (TL) Number | 027864 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 2 |
Sublot number | 7 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-09-07-73
DIME Test ID: 2022-09-07-73-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-09-26
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 09/19/2022
Method Performed: Mechanical Agitation - Method A
Mass of oven-dry sample in air for Sample 1: 1535.1 grams
Mass of sample in water for Sample 1: 885.5 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.363
Theoretical maximum density at 25°C (77°F): 147.1 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/26/2022 ✔