Summary for Test 2022-09-08-3-1

Test performed: CTM 521-June 2020
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 993150
DEA: 051G9704
EFIS: 0516000008
DIST-CO-RTE-PM05-SB-135-11.7/17.8
Award Date09/27/2021
Closeout Date03/28/2023
Work DescriptionCOLD PLANE, OVERLAY ROADWAY WITH RHMA (GAP GRADED) AND ADA CURB RAMPS.
Location DescriptionSANTA BARBARA COUNTY IN AND NEAR SANTA MARIA FROM LAKEVIEW ROAD TO NORTH SANTA MARIA CONNECTOR
QA Service Level1 (Verified on 08/09/2021)

Sample Information

Sample Taken Date09/08/2022 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing09/08/2022 Sample typeQuality Assurance
A brief description of the sampleClass 2 Concrete The quantity of what the sample constitutes10.5 Cy
From where was the sample collectedJob Site First name of sampler or witnessed byIsaac
Last name of sampler or witnessed byGleffe Title of samplerARET
Telephone number of sampler18053191237 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalportland/Donaven
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number590GN1010
The truck number from where the sample was collectedload 1 The batch plant ticket number from where the sample was collected1735273
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischard fron concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-09-08-3
DIME Test ID: 2022-09-08-3-1
Testing Lab: CT D05 - Santa Maria Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-09-22

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Salvador Lopez-Zamora
Date of test: 09/08/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 109803 lb
Maximum load on cylinder 2: 118959 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 678 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3870.4 psi
Compressive strength of cylinder 2: 4208.0 psi
Compressive strength (to nearest 10 psi): 4040 psi
General comments (publicly viewable) (Max 1000 characters): Complies

Test was verified on 9/22/2022 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.