Summary for Test 2022-07-06-75-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for storing JMF sample data |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/06/2022 | Sample Unique Key | 75 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/06/2022 |
| Sample type | Verification | A brief description of the sample | 2 bags of Combined RAP |
| The quantity of what the sample constitutes | JMF Renewal | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ward | Last name of sampler or witnessed by | Jenkins |
| Title of sampler | Not set | Telephone number of sampler | Not set |
| Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | JF Shea Construction - Fawndale Rock and Asphalt - Redding CA | Transportation Laboratory (TL) Number | Not set |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Fawndale |
|---|---|---|---|
| Aggregate Size | Not set | Aggregate Source | Not set |
| RAP Stockpile | Not set | Stockpile Size (tons) | Not set |
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-06-75
DIME Test ID: 2022-07-06-75-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-09-22
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Arthur Mills
Date of test: 07/13/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.7 grams
Mass of oven-dry sample in air for Sample 1: 1583.8 grams
Mass of container filled with the sample and water for Sample 1: 8293.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.532
Theoretical maximum density at 25°C (77°F): 157.6 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/22/2022 ✔