Summary for Test 2022-09-07-60-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 994186
DEA: 010L0504
EFIS: 0121000047
MINOR: 01A6165
DIST-CO-RTE-PM01-DN-199-11.0/11.5
Award DateNot set
Closeout Date05/03/2024
Work DescriptionPlace High Friction Surface Treatment
Location DescriptionOn State Highway In Del Norte County from Hardscrabble Creek Bridge #01-40 to 0.5 mile north of Hardscrabble Creek Bridge
QA Service Level1 (Verified on 08/16/2022)

Sample Information

Sample Taken Date09/07/2022 Sample Unique Key60
Date that the sample was received by the laboratory/organization performing the testing09/16/2022 Sample typeDepartment Acceptance
A brief description of the sample64-16 R15 JMF The quantity of what the sample constitutes1 can
From where was the sample collectedFabricator First name of sampler or witnessed byLoren
Last name of sampler or witnessed byLee Title of samplerConsultant
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTidewater Smith River
Transportation Laboratory (TL) Number364384 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt - Klamath Falls Plant - Klamath Falls OR MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-09-07-60
DIME Test ID: 2022-09-07-60-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-09-21

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 09/21/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 31.724 kPa
Phase Angle (δ) (for the 10 cycles): 51.4 degree
Complex Modulus (G*) (for the 10 measurements): 3172.433 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 2479 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 9/21/2022 ✔