Summary for Test 2022-09-07-63-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993299 DEA: 022J3904 EFIS: 0221000073 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-44-45.5/51.6 |
| Award Date | 11/16/2021 |
| Closeout Date | 11/23/2022 |
| Work Description | HMA OVERLAY, REPLACE AC SURFACING AND SHOULDER BACKING. |
| Location Description | SHASTA COUNTY NEAR VIOLA FROM 3.0 MILES EAST OF DEER FLAT ROAD TO 0.5 MILE EAST OF BRIDGE CREEK ROAD |
| QA Service Level | 1 (Verified on 10/18/2021) |
Sample Information
| Sample Taken Date | 09/07/2022 | Sample Unique Key | 63 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2022 |
| Sample type | Department Acceptance | A brief description of the sample | 2 bags of Fine RAP |
| The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | JD | Last name of sampler or witnessed by | Atkinson |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D79153B | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis – Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 857909 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | 3/8 inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-09-07-63
DIME Test ID: 2022-09-07-63-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-09-22
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Karen Dorado
Date of test: 09/14/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.8 grams
Mass of oven-dry sample in air for Sample 1: 1637.1 grams
Mass of container filled with the sample and water for Sample 1: 8320.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.509
Theoretical maximum density at 25°C (77°F): 156.2 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/22/2022 ✔