Summary for Test 2022-09-02-43-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date09/02/2022 Sample Unique Key43
Date that the sample was received by the laboratory/organization performing the testing09/08/2022 Sample typeQuality Assurance
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutes3 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byJ
Last name of sampler or witnessed byLight Title of samplerASR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUnknown
Transportation Laboratory (TL) Number203181 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberUnknown
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedChute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-09-02-43
DIME Test ID: 2022-09-02-43-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-09-16

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 09/16/2022
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.03 in
Maximum load on cylinder 1: 69705 lbf
Maximum load on cylinder 2: 67663 lbf
Maximum load on cylinder 3: 73827 lbf
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.76 in^2
Compressive strength of cylinder 1: 5519.0 psi
Compressive strength of cylinder 2: 5384.0 psi
Compressive strength of cylinder 3: 5788.0 psi
Compressive strength (to nearest 10 psi): 5560 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Cylinder Code 1 of 3

Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3

Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3

Test was verified on 9/16/2022