Summary for Test 2022-08-22-74-8
Test performed: AASHTO T315-22Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/22/2022 | Sample Unique Key | 74 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/23/2022 | Sample type | Quality Control |
| A brief description of the sample | Tank 3410 | The quantity of what the sample constitutes | 1 of 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Molly |
| Last name of sampler or witnessed by | Gibney | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | AC-270-2133 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Redding, CA | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | VSS Emultech - Redding CA | Multigrade | Yes |
| Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2022-08-22-74
DIME Test ID: 2022-08-22-74-8
Testing Lab: VSS Emultech - Redding
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-09-15
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: Molly Gibney
Date of test: 08/26/2022
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 0.0 degree
(G*) x sin(δ)=: 2320 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/15/2022 ✔