Summary for Test 2022-09-08-25-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 993801
DEA: 032G3704
EFIS: 0321000118
DIST-CO-RTE-PM03-COL,YOL-16-0.1/7.3,0.0/0.7
Award Date06/27/2022
Closeout Date07/26/2023
Work DescriptionPARTIAL DEPTH RECYCLING, PLACE RHMA-G, & COLD PLANE AC PAVEMENT.
Location DescriptionCOLUSA AND YOLO COUNTIES NEAR RUMSEY FROM 0.1 MILE SOUTH OF ROUTE 20 TO 1.3 MILES NORTH OF ROAD 40
QA Service Level1 (Verified on 05/09/2022)

Sample Information

Sample Taken Date09/08/2022 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing09/12/2022 Sample typeDepartment Acceptance
A brief description of the sampleCSS1h The quantity of what the sample constitutes2 jugs
From where was the sample collectedJob Site First name of sampler or witnessed byPepo
Last name of sampler or witnessed byRodrigues Title of samplerOperator Engineer
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAlbina Asphalt
Transportation Laboratory (TL) Number042924 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeCSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2022-09-08-25
DIME Test ID: 2022-09-08-25-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2022-09-14

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 09/12/2022
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 456.2 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 423.1 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 451.4 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 418.5 g
Beaker 1 Residue: 66.2 %
Beaker 2 Residue: 65.8 %
Percentage of residue: 66 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/14/2022 ✔