Summary for Test 2022-08-30-79-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 993354 DEA: 023J1204 EFIS: 0222000010 |
|---|---|
| DIST-CO-RTE-PM | 02-BUT,BUT/PLU-70-22/45 (PLU), 4/45 |
| Award Date | 07/26/2021 |
| Closeout Date | 07/27/2023 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
| Sample Taken Date | 08/30/2022 | Sample Unique Key | 79 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/30/2022 | Sample type | Department Acceptance |
| A brief description of the sample | 4 bags of 3/4-inch Class 2 Aggregate Base for use in Structural Backfill | The quantity of what the sample constitutes | Structural Backfill? |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Dave |
| Last name of sampler or witnessed by | Lockett | Title of sampler | Consultant |
| Telephone number of sampler | Laboratory sample identification | D79146 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Materials | |
| Transportation Laboratory (TL) Number | 036612 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Vulcan Materials |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Manufacturing Facility | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-30-79
DIME Test ID: 2022-08-30-79-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-09-12
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Arthur Mills, Karen Dorado
Date of test: 09/01/2022
| Sieve Size | Individual Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 795.0 grams | 93.9 % | |||||
| 1229.0 grams | 85 % | |||||
| 3562.0 grams | 57 % | |||||
| 174.1 grams | 36 % | |||||
| 105.0 grams | 24 % | |||||
| 61.2 grams | 17 % | |||||
| 37.0 grams | 12 % | |||||
| 23.3 grams | 10 % | |||||
| 15.1 grams | 7.7 % | |||||
| 65.2 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/12/2022 ✔