Summary for Test 2022-08-31-39-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 993847 DEA: 081M8604 EFIS: 0822000056 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-180.2/186.2 |
| Award Date | 06/23/2022 |
| Closeout Date | 12/12/2022 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HMA (GAP GRADED). |
| Location Description | SAN BERNARDINO COUNTY ABOUT 43 MILES NORTH OF BAKER FROM 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING TO NEVADA STATE LINE |
| QA Service Level | 1 (Verified on 12/05/2022) |
Sample Information
| Sample Taken Date | 08/31/2022 | Sample Unique Key | 39 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/01/2022 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA A |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | larry | Last name of sampler or witnessed by | francisco |
| Title of sampler | TE | Telephone number of sampler | |
| Laboratory sample identification | test 1 150tons out at 0912 PM | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Las Vegas Paving | Transportation Laboratory (TL) Number | 1 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 5 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 5 | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-08-31-39
DIME Test ID: 2022-08-31-39-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-09-12
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Minh Pham
Date of test: 09/01/2022
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| 0 % | ||||||
| 0 % | ||||||
| 100 % | ||||||
| 89 % | ||||||
| 76 % | ||||||
| 70 % | ||||||
| 46 % | ||||||
| 34 % | ||||||
| 26 % | ||||||
| 21 % | ||||||
| 15 % | ||||||
| 8 % | ||||||
| 4.5 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/12/2022 ✔