Summary for Test 2022-08-22-61-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 993576
DEA: 09389604
EFIS: 0921000043
DIST-CO-RTE-PM09-MNO,INY-6,168-0.8/4.9,30.0/33.5
Award Date04/25/2022
Closeout Date11/01/2022
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA (TYPE A).
Location DescriptionMONO AND INYO COUNTIES ON ROUTE 6 NEAR CHALFANT FROM 2.5 MILES WEST OF CHALFANT LOOP ROAD TO 0.2 MILE EAST OF BROWN SUBDIVISION ROAD AND ON ROUTE 168 ABOUT 12 MILES EAST OF BIG PINE FROM 1.3 MILES WEST TO 1.7 MILES EAST OF WHITE MOUNTAIN ROAD
QA Service Level1 (Verified on 02/21/2022)

Sample Information

Sample Taken Date08/22/2022 Sample Unique Key61
Date that the sample was received by the laboratory/organization performing the testing08/29/2022 Sample typeDepartment Acceptance
A brief description of the samplePG 64-28M The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byGranite
Last name of sampler or witnessed by_ Title of samplerOiler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Bishop
Transportation Laboratory (TL) Number999916 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank number
Time of sampleAM HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-08-22-61
DIME Test ID: 2022-08-22-61-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-09-12

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 09/07/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 20.884 kPa
Phase Angle (δ) (for the 10 cycles): 56.4 degree
Complex Modulus (G*) (for the 10 measurements): 2088.423 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 1739 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 9/12/2022 ✔