Summary for Test 2016-08-01-7-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-171.8/173.8 |
| Award Date | 11/04/2015 |
| Closeout Date | 08/21/2018 |
| Work Description | BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT. |
| Location Description | In SBD County |
| QA Service Level | 1 (Verified on 10/19/2015) |
Sample Information
| Sample Taken Date | 08/01/2016 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/02/2016 | Sample type | Department Acceptance |
| A brief description of the sample | Structure Backfill | The quantity of what the sample constitutes | 2 Bags |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Rene |
| Last name of sampler or witnessed by | Unknown | Title of sampler | Field Technician |
| Telephone number of sampler | Unknown | Laboratory sample identification | 6302B |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Native Material |
| Transportation Laboratory (TL) Number | C 974880 | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Sta 85 50 to 86 25 Stockpile |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2016-08-01-7
DIME Test ID: 2016-08-01-7-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-06-06
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Jose Guzman
Date of test: 08/08/2016
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 98 % | ||||||
| 96 % | ||||||
| 92 % | ||||||
| 86 % | ||||||
| 82 % | ||||||
| 70 % | ||||||
| 58 % | ||||||
| 46 % | ||||||
| 36 % | ||||||
| 27 % | ||||||
| 20 % | ||||||
| 15 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/30/2019 ✔