Summary for Test 2022-09-02-11-4
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 993730 DEA: 010K7704 EFIS: 0121000008 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-101,162-14.6,15.9,0.7 |
| Award Date | 06/15/2022 |
| Closeout Date | 07/21/2023 |
| Work Description | Repair 3 Bridges |
| Location Description | MENDOCINO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 04/19/2022) |
Sample Information
| Sample Taken Date | 09/02/2022 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2022 |
| Sample type | Department Acceptance | A brief description of the sample | #5 Barsplice Grip Twist Coupler |
| The quantity of what the sample constitutes | 124 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
| Title of sampler | qa | Telephone number of sampler | 916 517 0532 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Camblin | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | s19-520-22 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | cascade |
| Coupler Manufacturer | barsplice | Intermediate Assembler or Fabricator | camblin |
| Rebar Size | #5 | Coupler Model | grip twist |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | male 212556 female 212556 | Rebar Heat Number(s) | 306422 |
| Rebar Size 2 | 5 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2022-09-02-11
DIME Test ID: 2022-09-02-11-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2022-09-08
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/08/2022
UTM: 450kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | No. 5/16mm | 1 | 0 | 0.31 | 27570 | 88935 | Service Splice | bewing |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 9/8/2022 ✔
