Summary for Test 2022-08-29-53-3
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 993299 DEA: 022J3904 EFIS: 0221000073 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-44-45.5/51.6 |
| Award Date | 11/16/2021 |
| Closeout Date | 11/23/2022 |
| Work Description | HMA OVERLAY, REPLACE AC SURFACING AND SHOULDER BACKING. |
| Location Description | SHASTA COUNTY NEAR VIOLA FROM 3.0 MILES EAST OF DEER FLAT ROAD TO 0.5 MILE EAST OF BRIDGE CREEK ROAD |
| QA Service Level | 1 (Verified on 10/18/2021) |
Sample Information
| Sample Taken Date | 08/29/2022 | Sample Unique Key | 53 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/29/2022 | Sample type | Department Acceptance |
| A brief description of the sample | 1 bag of Combined RAP | The quantity of what the sample constitutes | Production Start-Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Cindy |
| Last name of sampler or witnessed by | Bryant | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D79143B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tullis – Northstate Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 866065 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate Asphalt |
|---|---|---|---|
| Aggregate Size | 1/2-inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-29-53
DIME Test ID: 2022-08-29-53-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2022-09-09
Test Results
Does this test use 1/4 sieve?: Yes
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Khue Yang
Date of test: 09/06/2022
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1953.3 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 39.5 grams | 98 % | |||||
| 348.7 grams | 82.1 % | |||||
| 619.7 grams | 68.3 % | |||||
| 898.6 grams | 54 % | |||||
| 1025.9 grams | 47.5 % | |||||
| 1274.7 grams | 34.7 % | |||||
| 1457.0 grams | 25.4 % | |||||
| 1586.0 grams | 18.8 % | |||||
| 1684.6 grams | 13.8 % | |||||
| 1753.8 grams | 10.2 % | |||||
| 1801.1 grams | 7.8 % | |||||
General comments (publicly viewable) (Max 1000 characters): Uncorrected
Test was verified on 9/9/2022 ✔