Summary for Test 2022-03-18-60-3
Test performed: CTM 557-June 2020Project Information
| Project Identifiers | Project ID: 211260 DEA: 072159U4 EFIS: 0715000160 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,ORA-5-0.0/1.5, 44.3/44.4 |
| Award Date | 05/27/2016 |
| Closeout Date | 08/01/2023 |
| Work Description | CONSTRUCT HOV LANES AND MIX FLOW LANES. |
| Location Description | LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK |
| QA Service Level | 1 (Verified on 03/16/2016) |
Sample Information
| Sample Taken Date | 03/18/2022 | Sample Unique Key | 60 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/19/2022 | Sample type | Quality Control |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 6 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Dustin |
| Last name of sampler or witnessed by | Fox | Title of sampler | QC Field Technician |
| Telephone number of sampler | Unknown | Laboratory sample identification | Set 1 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Jobsite |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | 00-0000 | Structure name | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G3-15-STR-002 |
|---|---|---|---|
| The truck number from where the sample was collected | Load 2 | The batch plant ticket number from where the sample was collected | 0 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Set 1 |
| A detailed description of where the material sample was collected | 10000 Austin Vault, Easterly Wall of Vault | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2022-03-18-60
DIME Test ID: 2022-03-18-60-3
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Test Release Date: 2022-09-07
Test Results
Input Type: Calculated
Tester's full name: Dustin Fox
Date of test: 03/18/2022
Temperature: 78 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/7/2022 ✔