Summary for Test 2022-08-25-51-1

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 993387
DEA: 07323404
EFIS: 0716000064
DIST-CO-RTE-PM07-LA-5-R59.5/R67.9
Award Date02/25/2022
Closeout Date06/30/2026
Work DescriptionPLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date08/25/2022 Sample Unique Key51
Date that the sample was received by the laboratory/organization performing the testing08/25/2022 Sample typeQuality Assurance
A brief description of the sampleClass 3 Aggregate Base The quantity of what the sample constitutes18,000 SQ FT.
From where was the sample collectedJob Site First name of sampler or witnessed byIan
Last name of sampler or witnessed bySnyder Title of samplerField Materials Tester
Telephone number of sampler15628339318 Laboratory sample identification22-2252
Linked DIME Sample ID The fabricator/manufacturer/facility nameClass 3 Aggregate Base
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedIn-placed material
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-08-25-51
DIME Test ID: 2022-08-25-51-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2022-08-30

Test Results


Is oversize material: No
Input Type: Calculated
Tester's full name: Ian Snyder
Date of test: 08/25/2022
In-place wet density: 2.20
Highest adjust wet density: 2.30
% Moisture: 9.5 %
Optimum Moisture: 13.5 %
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters): In-place wet density of 2.20 vs maximum wet density of 2.30.

Test was verified on 8/30/2022 ✔