Summary for Test 2022-08-18-48-1

Test performed: AASHTO T59-16

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date08/18/2022 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2022
Sample typeQuality Assurance A brief description of the sampleTack Coat
The quantity of what the sample constitutes1 Oil Jug From where was the sample collectedJob Site
First name of sampler or witnessed bySergio Last name of sampler or witnessed byTostado
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namepacific northwest oil Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2022-08-18-48
DIME Test ID: 2022-08-18-48-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2022-08-30

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 08/25/2022
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 445.4 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 416 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 445.9 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 416.4 g
Beaker 1 Residue: 58.8 %
Beaker 2 Residue: 59 %
Percentage of residue: 59 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/30/2022