Summary for Test 2022-08-21-1-2
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 993771 DEA: 07325204 EFIS: 0716000082 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R36.7/R37.1 |
Award Date | 02/15/2022 |
Closeout Date | 01/29/2024 |
Work Description | San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs |
Location Description | Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING |
QA Service Level | 1 (Verified on 04/21/2022) |
Sample Information
Sample Taken Date | 08/21/2022 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/23/2022 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Vantine |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | 1044-2 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Flatiron | Transportation Laboratory (TL) Number | Set 2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | Not Provided |
---|---|---|---|
The truck number from where the sample was collected | Not Provided | The batch plant ticket number from where the sample was collected | Not Provided |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Site | Where the material sample would have been placed if not sampled | Hinge and Deck |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-08-21-1
DIME Test ID: 2022-08-21-1-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-08-28
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Mendez
Date of test: 08/28/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 171465 lb
Maximum load on cylinder 2: 168600 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6065.3 psi
Compressive strength of cylinder 2: 5963.9 psi
Compressive strength (to nearest 10 psi): 6010 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/28/2022 ✔