Summary for Test 2022-02-24-32-1

Test performed: AASHTO T336-15

Project Information

Project IdentifiersProject ID: 214951
DEA: 120K0234
EFIS: 1214000100
DIST-CO-RTE-PM12-ORA-5-17.1/18.9
Award Date09/23/2020
Closeout Date02/09/2026
Work DescriptionSouth County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/01/2020)

Sample Information

Sample Taken Date02/24/2022 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing02/25/2022 Sample typeQuality Control
A brief description of the sampleJPCP Field Qualification The quantity of what the sample constitutes65
From where was the sample collectedJob Site First name of sampler or witnessed byBrandon
Last name of sampler or witnessed bySchroeder Title of sampler
Telephone number of sampler Laboratory sample identificationW01-22-04040-C1
Linked DIME Sample ID The fabricator/manufacturer/facility nameTwining
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number3F5FL001
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected108157490
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedI-5 SB Alicia Parkway Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-02-24-32
DIME Test ID: 2022-02-24-32-1
Testing Lab: Atkinson Construction
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Test Release Date: 2022-08-24

Test Results


Input Type: Calculated
Tester's full name: Mark Torres
Date of test: 03/31/2022
Average CTE: .00000884 mm/mm/°C
Average CTE: 4.913E-6 in/in/°F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/24/2022 ✔