Summary for Test 2022-08-16-33-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award Date04/03/2020
Closeout Date06/06/2024
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date08/16/2022 Sample Unique Key33
Date that the sample was received by the laboratory/organization performing the testing08/16/2022 Sample typeDepartment Acceptance
A brief description of the sample3/8" HMA-A DIKE The quantity of what the sample constitutes18 tons
From where was the sample collectedManufacturer First name of sampler or witnessed byAvo
Last name of sampler or witnessed byKarajian Title of samplerTET
Telephone number of sampler Laboratory sample identification22-0229
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials Sun Valley
Transportation Laboratory (TL) Number019430 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/8 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-08-16-33
DIME Test ID: 2022-08-16-33-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-08-18

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 08/18/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1601.4 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1498.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 6.40 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/18/2022