Summary for Test 2022-08-07-4-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 993732
DEA: 010K9804
EFIS: 0121000038
DIST-CO-RTE-PM01-MEN-101-64.9/69.3
Award Date06/16/2022
Closeout Date10/04/2022
Work DescriptionREPLACE ASPHALT CONCRETE SURFACING; GEOSYNTHETIC PAVEMENT INTERLAYER.
Location DescriptionMENDOCINO COUNTY AT AND NEAR LAYTONVILLE FROM 1.6 MILES SOUTH TO 2.5 MILES NORTH OF TEN MILE CREEK BRIDGE
QA Service Level1 (Verified on 04/19/2022)

Sample Information

Sample Taken Date08/07/2022 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing08/08/2022 Sample typeDepartment Acceptance
A brief description of the sampleR25 PG58-22 The quantity of what the sample constitutes1 Can
From where was the sample collectedFabricator First name of sampler or witnessed byR
Last name of sampler or witnessed byMelvin Title of samplerConsultant
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Ukiah
Transportation Laboratory (TL) Number033178 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number1
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 58-22 / PG 58-16 Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-08-07-4
DIME Test ID: 2022-08-07-4-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-19

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/17/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 41.614 kPa
Phase Angle (δ) (for the 10 cycles): 46.6 degree
Complex Modulus (G*) (for the 10 measurements): 4161.043 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 3023 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 8/19/2022 ✔